Categories
OEZ (https://www.oez.com/)

Overvoltage protections

SJB-25E-3-MZS

Order Code: OEZ:38357
Lightning current arrester, type 1+2, Iimp 25 kA, Uc AC 350 V, connection 3+0, replaceable modules, with signalling, spark gap SJB-25E-3-MZS

SJB-25E-3N-MZS

Order Code: OEZ:38358
Lightning current arrester, type 1+2, Iimp 25 kA, Uc AC 350 V, connection 3+1, replaceable modules, with signalling, spark gap SJB-25E-3N-MZS

SJB-50E-1-MZS

Order Code: OEZ:45559
Lightning current arrester, type 1+2, Iimp 50 kA, Uc AC 264 V, connection 1+0, replaceable modules, with signalling, spark gap SJB-50E-1-MZS

SJB-50E-1N-MZS

Order Code: OEZ:45560
Lightning current arrester, type 1+2, Iimp 50 kA, Uc AC 264 V, connection 1+1, replaceable modules, with signalling, spark gap SJB-50E-1N-MZS

SJB-25E-1-M

Order Code: OEZ:38360
Replaceable module, type 1+2, spare part, Iimp 25 kA, Uc AC 350 V, only replaceable module, spark gap, for SJB-25E (L/N,... SJB-25E-1-M

SJB-50E-1-M

Order Code: OEZ:45561
Replaceable module, type 1+2, spare part, Iimp 50 kA, Uc AC 264 V, only replaceable module, spark gap, for SJB-50E (L/N,... SJB-50E-1-M

SJBC-25E-3-MZS

Order Code: OEZ:38361
Combined lightning current and surge voltage arrester, type 1+2, Iimp 25 kA, Uc AC 350 V, connection 3+0, replaceable modules, with signalling, spark gap, ... SJBC-25E-3-MZS

SJBC-25E-3N-MZS

Order Code: OEZ:38362
Combined lightning current and surge voltage arrester, type 1+2, Iimp 25 kA, Uc AC 350 V, connection 3+1, replaceable modules, with signalling, spark gap, ... SJBC-25E-3N-MZS

SVBC-12,5-3-MZ

Order Code: OEZ:40619
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 3+0, replaceable modules, varistor SVBC-12,5-3-MZ

SVBC-12,5-3-MZS

Order Code: OEZ:40620
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 3+0, replaceable modules, with signalling, varistor SVBC-12,5-3-MZS

SVBC-12,5-3N-MZ

Order Code: OEZ:40621
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 3+1, replaceable modules, varistor, spark gap SVBC-12,5-3N-MZ

SVBC-12,5-3N-MZS

Order Code: OEZ:40622
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 3+1, replaceable modules, with signalling, varistor,... SVBC-12,5-3N-MZS

SVBC-12,5-4-MZ

Order Code: OEZ:40623
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 4+0, replaceable modules, varistor SVBC-12,5-4-MZ

SVBC-12,5-4-MZS

Order Code: OEZ:40624
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 4+0, replaceable modules, with signalling, varistor SVBC-12,5-4-MZS

SVBC-12,5-1-MZ

Order Code: OEZ:40615
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 1+0, replaceable modules, varistor SVBC-12,5-1-MZ

SVBC-12,5-1N-MZS

Order Code: OEZ:40618
Combined lightning current and surge voltage arrester, type 1+2, Iimp 12,5 kA, Uc AC 335 V, connection 1+1, replaceable modules, with signalling, varistor,... SVBC-12,5-1N-MZS

SJB-N25E-1-M

Order Code: OEZ:38363
Replaceable module, type 1+2, spare part, Iimp 25 kA, Uc AC 350 V, only replaceable module, spark gap, for SJBC-25E (L/N... SJB-N25E-1-M

SVC-N350-1-M

Order Code: OEZ:38364
Replaceable module, type 2, spare part, Imax 40 kA, Uc AC 350 V, only replaceable module, varistor, for SJBC-25E (L/N, L... SVC-N350-1-M

SJB-100E-N-M

Order Code: OEZ:38359
Replaceable module, type 1+2, spare part, Iimp 100 kA, Uc AC 350 V, only replaceable module, spark gap, for SJB-25E, SJB... SJB-100E-N-M

SVBC-12,5-1-M

Order Code: OEZ:40625
Replaceable module, type 1+2, spare part, Iimp 12,5 kA, Uc AC 335 V, only replaceable module, varistor, for SVBC-12,5 (L... SVBC-12,5-1-M